Structural Load Analysis in PhiladelphiaStrucTech Structural Engineers
Renovation, change-of-use, rooftop additions.
StrucTech is a Philadelphia structural engineering firm led by Jim Clancy, PE #42340. Quick-turn structural analysis for permit applications, renovations, mechanical equipment, and change-of-use projects.
Scope of work
Most of this work starts with a permit application that came back asking for engineering. You want to take out a bearing wall, add a floor, put solar or an HVAC unit on the roof, or convert a warehouse into apartments. The reviewer needs to see that the existing structure can carry it, and that requires calculations under a PE seal.
Existing buildings rarely come with usable drawings, so we build the analysis from the field. We measure member sizes and spans, identify framing type and direction, check bearing conditions, and verify material where it matters. Prior alterations show up constantly in Philadelphia stock, and an unpermitted beam swap from twenty years ago changes the answer, so we look for them rather than assuming the original condition.
From there we establish current capacity and compare it against the proposed loading. That covers new dead load from finishes and equipment, live load changes from a change of use, roof loads including snow drift against parapets and adjacent structures, and lateral considerations where the alteration affects bracing or a shear element. If the existing framing works, we say so and document why. If it does not, we design the reinforcement: new beams and columns, sistered joists, header sizing over new openings, or a distribution frame for rooftop equipment.
The deliverable is a stamped package that a plans examiner can approve: calculations, framing plans and details as needed, and specified connections. We keep the scope tight to what the permit requires so you are not paying for a full building analysis when the question is one wall. Turnaround is usually days, not weeks, because these projects are almost always waiting on us.
Send your drawings, photos, or the reviewer's comments through the contact form, or call (267) 310-1172 and we will scope the analysis on the phone.
- Existing capacity analysis
- New load review
- Roof equipment & solar
- Wall openings & beams
- Stamped permit drawings
Structural Load Analysis across Philadelphia neighborhoods
How It Works
Simple, fast, on-record.
Call or Request
Reach a real engineer — same day for emergencies.
Site Assessment
On-site inspection, photos, and condition documentation.
Stamped Report
PE-sealed letter or report formatted for L&I submission.
Permit Cleared
We support the permit through pickup and re-inspection.
Structural Load Analysis questions
When do I need a structural load analysis?
When you remove or open a bearing wall, add a floor or roof deck, set new rooftop mechanical units, or change a space to a heavier use. Any time the loads change, the framing has to be checked.
Can you analyze a building that has no original drawings?
Yes, and in older Philadelphia buildings that is the normal case. We measure framing in the field, verify materials, and build the capacity model from what is actually there.
Will L&I accept a load analysis for a permit?
A permit reviewer needs stamped calculations they can follow. We present the existing capacity, the new loads, and the conclusion clearly, and we include Structural Plans/Drawings when a reinforcement design is part of the fix.
What if the analysis shows the framing is not strong enough?
Then we design the fix. That might be sistered joists, a new beam and posts, steel reinforcement, or a revised equipment location. You get a buildable solution, not just a failing number.
Permit on hold? Structure unsafe? Don't wait.
Get In Touch
Request an Engineer
Tell us about the project. We'll reach back fast — same day for active permits and emergencies.
Or call us directly: (267) 310-1172