Facade Inspection (5-Year) in Center City, PA

Facade inspection is the code-required inspection every 5 years for buildings over 3 stories or 40 feet tall per Philadelphia Code Chapter 14-1600. This applies to many Fishtown buildings including converted mills that are 4-6 stories, Front Street mixed-use developments that are 4-8 stories, and some taller rowhouses with pilot-house construction pushing height over 40 feet. A Pennsylvania-licensed Professional Engineer or Registered Architect must inspect the entire building exterior including walls, parapets, cornices, balconies, fire escapes, signs, and awnings looking for deterioration, loose elements, cracks, spalling where concrete or brick breaks off, and any conditions that could cause falling debris. The inspection requires close-up access using aerial lift, scaffolding, or rope access for tall buildings, photo documentation of all defects, and a stamped report submitted to L&I certifying the building is safe or identifying required repairs. Buildings overdue for inspection receive L&I violations with accumulating fines until inspection is complete.

Make Safe Permits

Certified Civil Engineer

Fully Licensed & Insured

Certified Structural Engineer

What to Expect With Facade Inspection (5-Year)
  • Timeline: 1-2 days on-site for inspection, report delivered within 2-3 weeks. Small building that's 3-4 stories with simple facades equals 1 day on-site at 6-8 hours. Medium building that's 5-8 stories with masonry facades on all elevations equals 1-2 days at 8-16 hours total. Large building that's 8+ stories with complex facades and ornamentation equals 2-3 days at 16-24 hours. We schedule aerial lift rental or scaffolding, and inspection sequence includes ground-level documentation photographing entire building from all sides, roof inspection accessing from interior stair to inspect parapets and copings, aerial lift inspection driving lift around building perimeter raising and lowering to inspect each elevation section by section, close-up examination tapping bricks and probing mortar joints, and photo documentation with 100-300 photos typical.
  • Weather constraints are significant. Cannot use aerial lifts in winds over 20 mph since lift becomes unstable at elevation with operator in basket. Cannot inspect facades in rain since water masks defects and mortar testing is unreliable when wet. Cannot inspect in temperatures below 35°F since mortar is too cold to properly test. Philadelphia averages 15-20 high wind days per month in winter and spring. Best inspection months are May-June and September-October with moderate temperatures, lower wind speeds, and less rain.
  • Access challenges in Fishtown include Front Street buildings under Market-Frankford El with limited aerial lift positioning due to El support columns in sidewalk, narrow alleys behind buildings where sometimes aerial lift cannot fit requiring scaffolding or rope access, street closure permits required if aerial lift blocks traffic lane, party wall buildings with facades on two sides only since sides are shared walls, and retail ground floors requiring coordination with business hours to not block storefronts during peak business.
Facade Inspection (5-Year)
Why Facade Inspection (5-Year) Matters
  • Chapter 14-1600 requires inspection every 5 years and L&I tracks compliance. When inspection is due at 5 years from last inspection or from building completion for new construction, L&I sends notice to property owner. If owner doesn't hire engineer and submit report within 90 days, L&I issues violation with fines typically $300 per month accumulating until inspection is complete. Fines can reach $3,600-$7,200 if owner delays 12-24 months. Eventually L&I issues court summons requiring owner to appear before judge who can order inspection completion or impose additional penalties. Building cannot be sold with open L&I violations since title company won't close and buyer's lender won't approve loan.
  • Facade failure causes catastrophic liability. Brick or stone falling from 40-80 feet hits pedestrian on Frankford Avenue or Front Street which are high foot traffic areas in Fishtown. Result is death or catastrophic injury like skull fracture or spinal injury, wrongful death lawsuit of $5M-$20M, and criminal negligence charges if building owner knew facade was deteriorating and didn't repair. New York City Local Law 11 was enacted after Barnard College student was killed by falling masonry with Columbia University settling for $6M and NYC imposing stricter facade inspection requirements. Philadelphia enacted Chapter 14-1600 for same reason.
  • Deferred maintenance costs 5-10 times more than preventive repair. Typical inspection findings show minor mortar deterioration with joints cracking and mortar slightly recessed. If repaired now the cost is $8,000-$15,000 for repointing to grind out deteriorated mortar and replace with new mortar. If deferred 5 years, mortar deteriorates further with water infiltrating behind brick, brick faces spall from freeze-thaw damage, and steel lintels rust with expanding rust pushing bricks out. Now repair costs $40,000-$80,000 for extensive repointing, brick replacement, and lintel replacement. If deferred 10 years, facade failure occurs with section of wall bulging that must be demolished and rebuilt costing $100,000-$200,000+ for partial facade reconstruction.
Why Facade Inspection (5-Year) Matters
How StrucTech Handles Facade Inspection (5-Year)
  • We've completed 50+ facade inspections on buildings over 3 stories and know common Fishtown building types including converted mills from 1880s-1920s with heavy timber and masonry facades often 4-6 stories, Front Street mixed-use from 2010s-2020s construction at 4-8 stories with brick veneer over steel or concrete frame, historic commercial buildings from 1900s-1940s commercial strips along Frankford Avenue at 3-4 stories, and newer apartment buildings from 2015-2025 at 4-6 stories with variety of cladding materials. We know typical defects by building age with pre-1950 masonry showing mortar deterioration and brick spalling, 1950-1980 masonry showing freeze-thaw damage, and post-2000 construction showing brick veneer problems.
  • We use aerial lifts for close-up access on all elevations not just binoculars from ground. We rent 40-60 foot articulating boom lift and systematically inspect masonry walls by tapping bricks with hammer handle listening for hollow sound indicating loose unit, parapets and copings at top of building heavily exposed to weather, cornices and lintels as decorative elements and structural supports above windows and doors, balconies checking railing attachment and deck condition, fire escapes testing for loose connections and rust, and signs and awnings checking mounting and structural adequacy of supports.
  • We document defects with location-specific photography and categorization by severity. Immediate safety hazards like loose bricks that could fall or parapet leaning outward are flagged as Priority 1 in report with recommendation to repair within 30-90 days and emergency contact if situation is critical. Significant deterioration like extensive mortar loss or cracking indicating structural movement is Priority 2 with recommendation to repair within 1-2 years. Minor maintenance items like isolated mortar cracks or minor spalling are Priority 3 with recommendation to repair within 3-5 years that can wait until next inspection cycle. We provide repair cost estimates for each priority level based on current Philadelphia GC rates.
How StrucTech Handles Facade Inspection (5-Year)
Common Questions About Facade Inspection (5-Year)
How long does facade inspection take in Fishtown?
1-2 days on-site for most buildings. 3-4 story buildings at minimum height requiring inspection equal 6-8 hours on-site for 1 day. 5-8 story buildings equal 8-16 hours for 1-2 days. 9-15 story buildings rare in Fishtown but more common Center City equal 12-24 hours for 2-3 days. Report delivered 2-3 weeks after inspection. Expedited delivery at 1 week instead of 2-3 weeks adds premium.
Does inspection report satisfy L&I requirements?
Yes, our stamped report is submitted directly to L&I. Report includes all Chapter 14-1600 requirements with building identification, inspector qualifications with our PE license number and credentials, inspection methodology with aerial lift used and all elevations inspected, findings with detailed description of all defects by location and severity categorization, recommendations with repair priorities and estimated timelines, and professional certification with stamped statement that inspection was completed per code requirements. We submit PDF report to L&I electronically, provide copy to you, and confirm L&I receipt. L&I updates their records showing your building is compliant for next 5 years.
What buildings require 5-year facade inspection?
Any building over 3 stories or over 40 feet height in Philadelphia per Chapter 14-1600. This includes converted mills in Fishtown at most 4-6 stories, Front Street mixed-use buildings typically 4-8 stories, new apartment buildings at many 4-6 stories, pilot-house rowhouses if total height exceeds 40 feet measured from grade to top of parapet, and commercial buildings along Frankford Avenue at many 3-4 stories. Exempt are 1-2 story buildings and rowhouses under 40 feet total height at most traditional 2.5-3 story rowhouses that are 35-38 feet.
What happens if inspection finds serious problems?
We categorize by severity in report. Priority 1 immediate safety hazard means we call you same-day from inspection site if we find loose bricks, leaning parapet, or anything that could fall and injure someone. Report states immediate repair required within 30-90 days. You must hire contractor to make emergency repairs with temporary netting, loose brick removal, or parapet bracing. If you don't repair, L&I can red-tag building after receiving our report. Priority 2 significant deterioration means recommend repair within 1-2 years. Priority 3 minor maintenance means recommend repair within 3-5 years that can defer until next inspection cycle.
Can you inspect building during winter months?
Winter inspection is challenging due to weather constraints. Cannot use aerial lifts in winds over 20 mph with Philadelphia averaging 15-20 high wind days per month December-March, temperatures below 35°F unsafe for operator in basket at elevation with mortar testing unreliable in cold, or ice and snow conditions that are slippery and unsafe. Best inspection months are May-June and September-October with moderate temperatures, lower wind speeds, less rain, and fewer weather delays. If your 5-year deadline falls in winter December-March, we recommend scheduling early in October-November before winter or requesting extension from L&I to inspect in spring.

Our Simple Step by Step Process

Reliable Structural Engineering & Inspection Services handled start to finish.

DISCOVER WHAT Center City, PA CUSTOMERS HAVE TO SAY ABOUT StrucTech

OUR REVIEWS

REVIEW US

ON GOOGLE

Where We Provide

Facade Inspection (5-Year)

  • Center City, PA

  • Northern Liberties, PA

  • University City, PA

  • Main Line, PA

  • Graduate Hospital & Point Breeze, PA

  • South Philadelphia, PA

  • Center City, PA

  • Old City & Society Hill, PA

  • Manayunk & Roxborough, PA

  • Kensington & Port Richmond, PA

Other Services We Provide

Need something else? Check out the

other services we offer for Structural Engineering & Inspection Services.

What We Can Help You With.

Our Services

Special inspections

Special inspections are when a licensed structural engineer monitors your construction project to verify the work matches approved drawings and meets code requirements. Philadelphia requires this for any project using structural steel beams, concrete slabs, high-strength bolts, or structural welding. The inspector visits your site at critical stages during construction, documents what the contractor built, catches problems before they're covered up, and provides certification to L&I when the work is done. Without this certification, L&I won't issue your Certificate of Occupancy and you can't sell or rent the building. Most Fishtown projects over two stories need special inspections, and your architect lists exactly which inspections are required when they submit your permit application.

Learn More →
Underpinning Inspection

An Underpinning inspection is when a structural engineer monitors excavation work next to existing buildings to make sure neighboring properties don't collapse or settle. Philadelphia requires this whenever you dig deeper than 5 feet within 10 feet of an adjacent structure, which is basically every basement excavation in Fishtown's narrow rowhouse lots. Your contractor digs in small sections, pours concrete to support the neighbor's foundation in each section, then moves to the next section. This process repeats 16-24 times for a typical rowhouse. The engineer must be on-site during excavation and concrete placement for every single section to verify the work protects adjacent buildings. Without this documentation, L&I won't issue your Certificate of Occupancy, and if your neighbor's building settles or collapses, you're liable for all damages.

Learn More →
Foundation Inspections

A Foundation inspection is when a structural engineer assesses your building's foundation to identify problems and estimate repair costs. You need this before buying a property to know what you're getting into, before planning a renovation so your architect knows what they're working with, or when you've discovered problems like cracks in walls, doors sticking, floors sloping, or water coming through the basement. Most Fishtown rowhouses are 100-150 years old with stone or brick foundations from the 1800s-1950s. These foundations were fine when built but often show deterioration now from lime mortar crumbling, stones separating, freeze-thaw damage, or settlement from inadequate footings. The engineer accesses your basement and crawlspace, measures cracks, tests mortar condition, checks for water infiltration, documents settlement, and assesses whether the foundation is structurally adequate. You get an 8-15 page report with photos, detailed findings, and repair recommendations with cost estimates.

Learn More →
Make Safe Permits

Make safe permits are emergency L&I permits required when a building partially collapses, shows imminent collapse signs, or gets red-tagged as unsafe. When L&I red-tags a building under Section 110, you must obtain a make safe permit to perform emergency stabilization work like installing shoring, bracing walls, removing dangerous elements, or partial demolition. This permit requires a Pennsylvania-licensed structural engineer to design the emergency work, provide stamped drawings, supervise the stabilization, and certify completion to L&I. The make safe permit is processed on an emergency basis, typically issued within 24-48 hours rather than the normal 2-4 week permit review. Philadelphia averages 300 building collapses per year, many in Fishtown from adjacent excavation damage, roof overloading, fire damage, or century-old buildings deteriorating. Most make safe permit applications happen between 11pm and 3am when buildings collapse during construction, storms, or snow loading events.

Learn More →
Emergency Structural Engineering

Emergency structural engineering is the immediate response when your contractor discovers structural failure during renovation, a load-bearing element fails unexpectedly, or you need same-day structural assessment to keep your project moving. This is when you call us directly because your contractor removed what they thought was a non-load-bearing wall and the second floor sagged 2 inches, opened a wall and found severe termite damage, discovered the existing beam is undersized for the addition you're building, or noticed floor joists rotting where they meet the foundation. In Fishtown's 1800s-1950s rowhouses, contractors frequently discover hidden structural problems during demolition because previous homeowners covered problems with drywall rather than fixing them. The engineer responds within 2-4 hours, assesses damage on-site, designs temporary stabilization for the same day so your contractor can continue working tomorrow, and provides permanent repair drawings within 3-7 days so your project stays on schedule.

Learn More →
Slab Inspection

Mat slab inspection is the code-required inspection by a structural engineer before your contractor pours the foundation slab for new construction or basement excavation projects. Philadelphia Building Code Table 1705.3 requires special inspection of concrete reinforcement placement for most projects, with limited exceptions for simple 1-2 story buildings. Most Fishtown new construction like 3-4 story townhouses and Front Street mixed-use buildings require mat slab inspection. Your contractor excavates to foundation depth, installs vapor barrier and compacted stone base, places reinforcing steel in a rebar grid, and calls the engineer for inspection. The engineer arrives before concrete trucks (typically 6:30am for 7am pour), inspects rebar size, spacing, and cover distances, verifies excavation depth and preparation, approves or identifies corrections, and documents with photos. The contractor proceeds with concrete pour only after engineer approval, and the engineer submits a report to L&I for the permit file.

Learn More →
Concrete & Rebar Inspection

Concrete and rebar inspection is the special inspection required by Philadelphia Building Code Table 1705.3 for elevated slabs, concrete columns, concrete walls, beams, and any structural concrete element beyond simple ground-level foundations. Most Fishtown new construction projects require multiple concrete inspections throughout construction as each floor or structural element is formed and poured. This is different from mat slab inspection which is a one-time inspection before foundation pour. Concrete and rebar inspection happens repeatedly during construction as each floor slab, column, or wall is built. Your contractor builds formwork (temporary wooden forms that hold wet concrete), installs reinforcing steel per structural drawings, calls the engineer for inspection before pouring, and the engineer approves so concrete can be placed. This repeats for each floor slab, each column, and each wall that contains structural concrete, typically requiring 3-8 inspections for a 3-story Fishtown townhouse or 12-24+ inspections for larger buildings.

Learn More →
Structural Steel Inspection

Structural steel inspection is the special inspection required by Philadelphia Building Code Table 1705.2 when your project uses steel beams, columns, or structural frames. Most Fishtown renovation projects remove load-bearing walls to create open floor plans by installing steel I-beams to support the second floor. Most Front Street new construction uses structural steel frames with steel beams and columns supporting concrete slabs in 4-6 story mixed-use buildings. Table 1705.2 distinguishes between continuous inspection where the engineer is on-site during the entire operation (required for welded moment connections and high-strength bolted connections) and periodic inspection with scheduled visits (allowed for standard bolted connections and simple welds). Your contractor orders steel from a fabricator, steel is delivered to site, a crane lifts beams into place, connections are bolted or welded, and the engineer inspects at multiple stages. Typical steel projects require 2-4 inspections for small residential beam installations to 12-24+ inspections for large multi-story steel frame buildings.

Learn More →
Facade Inspection (5-Year)

Facade inspection is the code-required inspection every 5 years for buildings over 3 stories or 40 feet tall per Philadelphia Code Chapter 14-1600. This applies to many Fishtown buildings including converted mills that are 4-6 stories, Front Street mixed-use developments that are 4-8 stories, and some taller rowhouses with pilot-house construction pushing height over 40 feet. A Pennsylvania-licensed Professional Engineer or Registered Architect must inspect the entire building exterior including walls, parapets, cornices, balconies, fire escapes, signs, and awnings looking for deterioration, loose elements, cracks, spalling where concrete or brick breaks off, and any conditions that could cause falling debris. The inspection requires close-up access using aerial lift, scaffolding, or rope access for tall buildings, photo documentation of all defects, and a stamped report submitted to L&I certifying the building is safe or identifying required repairs. Buildings overdue for inspection receive L&I violations with accumulating fines until inspection is complete.

Learn More →
Excavation Shoring Inspection

Excavation shoring inspection is the code-required monitoring by a structural engineer when your contractor digs deeper than 5 feet and uses temporary support systems called shoring to prevent cave-ins. OSHA and Philadelphia Building Code require shoring for excavations over 5 feet deep or when excavating near existing structures to prevent soil from collapsing into the excavation, protect workers from being buried alive, and prevent adjacent buildings from settling. Most Fishtown basement excavations that lower basement floors to add ceiling height or dig new basements under existing buildings require shoring because you're digging 8-12 feet deep and working within inches of adjacent rowhouse foundations. Typical shoring systems are steel sheet piling with interlocking steel sheets driven into ground, soldier piles and lagging with vertical steel beams and horizontal wood planks, or trench boxes as steel cages protecting workers inside excavation. Your contractor installs shoring, the engineer inspects before excavation proceeds, the engineer monitors during excavation, and the engineer certifies shoring performed adequately.

Learn More →
Structural Load Analysis

Structural load analysis is the engineering calculation required when you're adding loads to an existing building or when your architect needs to verify existing structure can support proposed changes. Most Fishtown renovation projects involve structural modifications like removing walls between living room and kitchen to create open floor plan requiring beam to carry second floor load, adding third-floor addition or pilot house where existing structure must support additional story, converting rowhouse to multi-unit rental with heavier occupancy loads, or building rooftop deck where existing roof structure designed for snow only not people and furniture and planters. The engineer calculates existing structural capacity, calculates new loads being added, determines if existing structure is adequate, and designs strengthening if needed with new beams, columns, or foundation upgrades. Deliverables are stamped structural drawings showing required modifications and calculations for L&I permit review. This service is separate from inspection services which verify contractor builds what's on the drawings.

Learn More →
Building Structural Assessment

Building structural assessment is the comprehensive evaluation of your entire building's structural system before major renovations, after discovering problems, for property purchase due diligence, or when converting building use. Most Fishtown building assessments happen when developers buy older rowhouses sight-unseen at auction needing to know actual repair costs before committing capital, architects discover hidden damage during design phase like opened walls and found termite damage or rotted framing or previous unpermitted modifications, or property owners plan gut renovations wanting to know what structural surprises await before setting budgets. The engineer inspects foundation to roof including basement walls and floor framing and load-bearing walls and roof structure, identifies all structural deficiencies, categorizes by severity, and provides repair recommendations with cost estimates. This is different from foundation inspection which focuses only on foundation or pre-purchase home inspection which is general not structural-specific. Building structural assessment is engineering-level detailed inspection with stamped report typically 30-80 pages.

Learn More →

Not sure what you need?

Call us at +1 267-310-1172 and we'll help you figure it out.

Ready to Move Forward?

If you need Facade Inspection (5-Year)

or unsure and have questions let's talk.

We'll answer your questions, provide a clear estimate, and schedule a time that works for you.

Unable to find form